Chute Discharge Door

In case of fire, the link is melted and the door will roll or slam shut. NFPA 82 Section 6 has similar requirements for the chute intake door operation and latching mechanism as well as size limitations for the intake door. Trash chutes for apartments are long, vertical shafts that allow the trash to be disposed of on each floor . The intake on each floor often has a door to heighten safety measures. As residents dispose of their trash, it accumulates at the bottom in a dumpster or goes through a trash compactor. High-rise apartment buildings have dense populations, which means a ton of trash can accumulate quickly.
Using a control panel located at each trash chute door, the user selects the appropriate waste stream. Based on this selection, the sorter system automatically positions one or more deflector plates which directs the waste to the appropriate container. With our external steel chute system you Guillotine chute discharge door are getting more than a heavy duty chute – You’re getting an engineering triumph. High-rise, new construction and/or heavy-duty debris often require the use of our virtually indestructible steel chute. Overhead Door will design, install, rent and dismantle the system to meet your every need.

For one, we are the only manufacturer to provide a 100% stainless steel door as a standard. This makes for longer lasting, better looking and easier to maintain and clean doors. Rather than using a thinner, lesser quality material in the vent construction, we continue the same high quality material in the vented portion of the chute. They must self-close, they must self-latch, and they must be UL “B” Label doors with a 1.5-hour rating. This means that if the trash chute door is closed and latched, it will not fail for 90 minutes.
To help control potential noise, a sound dampening material can be applied to the outside of the metal chute. When combined with our internal trash chutes in multi-story buildings, the DuraSorter™ recycling sorter provides an easy method for sorting recyclables out of the waste stream. You can prevent many of the recyclable materials from entering the environment and reducing the negative impact that comes with contentious property manager. The system can be used in either new construction projects or installed as a retrofit to an existing trash chute system. By providing 2-hour fire-resistance-rated construction as described, the proposed design exceeds the code requirements, and we request that the proposed design be approved.

TrashChuteParts.com provides the best parts and products available to the professionals that service and maintain Trash Chutes and Laundry Chutes. Garbage chutes – All household waste should be wrapped and sealed tightly in plastic bags. As with chute washings, all solutions used are 100% biodegradable and environmentally friendly.
When planning a chute system, the best solution is to design it straight, with no offsets. When an offset is needed, it must be no greater than 15 degrees per NFPA code. Because the chute may act as a “chimney” for smoke, hot gases or fire and typically passes through multiple floors of a building, it is considered a shaft for code compliance. Every chute intake door must have a fire-protection rating to maintain the smoke and fire integrity of the shaft. Can be retrofitted to others chutes with spacers or sheet metal adaptors and mounting clips. Many modern trash chutes allow tenants to separate normal trash from recycling.

Putting forth the effort to keep your tenants healthy and happy increases the likelihood that they will stay in your building longer and reduces your liability. No laundry or rubbish chute shall be located in any stairwell nor within ten feet of any open stairway. The chute shall extend not less than four feet above the roof, and shall be covered with a metal skylight and plain glass or any approved automatic venting device.
All hopper discharges have a 2″ drain connection at the low point and are equipped with a top-hinged spring counter-balanced door with a fusible link hold open and a cam latch at the bottom allowing the door to washdown. This door is also UL 1 1/2 hour 2500F “B” labeled and is rated at 2500F temperature rise in 30 minutes. Additional #12GA reinforcing plates are available for high impact applications. In all buildings exceeding three stories in height and in institutional buildings every laundry and rubbish chute enclosure shall be of not less than two- hour fire-resistive construction. All chutes shall discharge directly into a room having walls, ceiling and floor of two-hour fire-resistive construction used solely for the reception of laundry or rubbish.
Maintaining a chute and all the parts is important, and that includes the doors on both ends. Latches and hinges on a building’s garbage chute must be checked on a regular basis. The trash chute doors should create a seal when shut to keep odors and germs in and smoke or flame from spreading in the event of a fire. A big part of chute maintenance falls on the residents because they are the individuals utilizing the chutes daily. Property and building managers often have signs posted at each intake door outlining what can and cannot be put through the trash chute and instructions on how to dispose of or break down certain items.

Any backup of materials could also cause damage to the chutes and also create a fire and smoke hazard as well. Automatic Brush Cleaning System, A cylindrical housing with replaceable stiff nylon brushes is automatically lowered and raised by a geared electric motor. The nylon brushes scrape and clean the internal surface as they move down and up the chute. The water supply for flushing the chute, the electric motor and the built in safety overloads, are all individually controlled by a robust electric logic control. A Trash/Linen/Garbage/Rubbish chute may differ from a Linen chute primarily in the way it terminates at the bottom, where the Garbage chute end into a trolley. Hotels and hospitals that use Linen chute install sorting tables at the bottom end of the chute to ensure that Linen can be sorted as it is received.